Non-Metallic Pipes
|
7.2.5.1. Asbestos-Cement Drainage Pipe and
Fittings
-
Except as provided in Sentence (2),
asbestos-cement pipe and its fittings for use in a drain, waste
or vent system shall conform to
-
Can/CGSB-34.22...or
-
CSA B127.1...
|
|
|
-
Asbestos-cement pipe and fittings used underground
either outside a building or under a building shall conform to Sentence
(1) or to
-
CAN/CGSB-34.9..,
-
CAN/CGSB-34.23..,
-
CSA B127.2...
7.2.6.2. Cast Iron Fittings for Asbestos-Cement
Drainage Pipe
-
Cast iron fittings designed for use with
asbestos-cement pipe for drainage purposes shall conform to the
applicable requirements of CSA B127.1... or CSA B127.2...
7.3.4.5. asbestos-cement
pipe is supported
-
at intervals not exceeding 2 000 mm or have two
supports for every 4 m length of pipe, and
-
at intervals not exceeding 1 000 mm where the
length of pipe between adjacent fittings is 300 mm or less.
|
7.2.5.3. Concrete Pipe and Fittings
-
Concrete pipe shall conform to CSA A257
Series, Standards for Concrete Pipe".
-
Joints with external elastomeric gaskets
shall be made with corrosion resistant external band type
flexible mechanical couplings that conform to
CAN/CSA-B602...
-
Concrete fittings field fabricated from
lengths of pipe shall not be used.
-
Concrete pipe shall not be used above
ground inside a building.
|
|
|
-
Precast reinforced circular concrete manhole
sections, catch basins and fittings shall conform to
CAN/CSA-A257.4-M...
|
7.2.5.4. Vitrified Clay Pipe and
Fittings
-
Vitrified clay pipe and fittings shall be
certified to CSA A60.1...
-
Couplings and joints for vitrified clay
pipe shall be certified to CSA A60.3...
-
Vitrified clay pipe and fittings shall not
be used except for an underground part of a drainage
system.
|
|
|
|