Mobile Homes and Solar Heating



7.4.6.5. Mobil Home Sewer Service

  1. A building sewer intended to serve a mobile home shall
  1. be not less than 4" size,
  2. be terminated above the ground,
  3. be provided with

i) a tamperproof terminal connection that is capable of being repeatedly connected, disconnected and sealed,

ii) a protective concrete pad, and

iii) a means to protect it from frost heave, and

  1. be designed and constructed in accordance with good engineering practice.

7.6.1.14. Mobile Home Water Service

  1. A water service pipe intended to serve a mobile home shall
  1. be not less than 3/4" size,
  2. be terminated above ground, and
  3. be provided with

i) a tamperproof terminal connection that is capable of being repeatedly connected, disconnected and sealed,

ii) a protective concrete pad,

iii) a means to protect it from frost heave, and

iv) a curb stop and a means of draining that part of the pipe located above the frost line when not in use.



7.2.10.13 Solar Domestic Hot Water

  1. Equipment for solar heating of potable water shall conform to CAN/CSA-F379.1, "Solar Domestic Hot Water Systems (Liquid ti Liquid Heat Transfer).


7.6.1.15 Solar Domestic Hot Water Systems

  1. Systems for solar heating of potable water shall be installed in conformance with CAN/CSA-F383, "Installation Code for Solar Domestic Hot Water Systems".
Home