Mobile Homes and Solar Heating
|

|
7.4.6.5. Mobil Home Sewer Service
-
A building sewer intended to serve a
mobile home shall
-
be not less than 4" size,
-
be terminated above the ground,
-
be provided with
i) a tamperproof terminal connection that
is capable of being repeatedly connected, disconnected and
sealed,
ii) a protective concrete pad, and
iii) a means to protect it from frost
heave, and
-
be designed and constructed in accordance
with good engineering practice.
|
|
7.6.1.14. Mobile Home Water Service
-
A water service pipe intended to serve a mobile
home shall
-
be not less than 3/4" size,
-
be terminated above ground, and
-
be provided with
i) a tamperproof terminal connection that is capable
of being repeatedly connected, disconnected and sealed,
ii) a protective concrete pad,
iii) a means to protect it from frost heave,
and
iv) a curb stop and a means of draining that part of
the pipe located above the frost line when not in use.
|

|
7.2.10.13 Solar Domestic Hot Water
-
Equipment for solar heating of potable
water shall conform to CAN/CSA-F379.1, "Solar Domestic Hot
Water Systems (Liquid ti Liquid Heat Transfer).
7.6.1.15 Solar Domestic Hot Water
Systems
-
Systems for solar heating of potable
water shall be installed in conformance with CAN/CSA-F383,
"Installation Code for Solar Domestic Hot Water
Systems".
|
|
|